BYE510.FX2 08/26/86 Fix number two for BYE510. 1.) For persons who desire to run RBBS as their .COM file (both COMFILE and RBBS set to YES) and with EXFILE also set to YES, you will find that BYE will not cycle properly for the next caller. To correct this problem, near the end of the main .ASM file you will find several conditional equates such as IF EXFILE AND METAL DB statements here of user area, filename, and 21 nuls ENDIF just add a conditional of the equivilent to IF EXFILE AND RBBS replacing the filename with that of your own exit file, or if NO exit file AND you are running CP/M PLUS (CPM3 set to YES) then use the filename of 'BYE COM'. ENDIF ;EXFILE AND RBBS 2.) If you are using a BANKED CP/M PLUS system, you may still utilize your own MDPREP/MDPOSP routines by reinstallation of the calls to them in the main program. The CALL MDPREP would be installed in the PATCH: area just before the CALL TBLADDR, and the CALL MDPOSP would be installed in the EXCPM: area just before the CALL RSXCLR. MOST of the CP/M Plus systems no longer need the pre- or post-processing routines. The Morrow HARD DISK SYSTEMS are an exception to this, so, Morrow users, keep this in mind for future versions, just in case the MDPREP/MDPOSP calls remain out. (We should be able to remember this!) It's looking great guys! THANKS!!! George Reding CompuServe [72436,45]